LogoASSAY
Environmental Testing
NELAP AccreditedISO 17025:201738 States

Molecule by molecule.
Every analyte. Every matrix.

Assay returns certified environmental reports that tell you exactly what's present and at what concentration — air, water, soil, bulk materials, or workplace air. Field collection to signed report in as little as 24 hours.

AIR DUCT — HVAC SECTION 4BPM2.50–2 ft2–5 ftTPPH ↑SOIL CORE / SPLIT-SPOONFLOW-THRUCOUPONWATER DISTRIBUTION — PFAS SAMPLING PTPb LAYER1978–ERAXRFWALL SECTION / LEAD PAINTPCB XFMRCONTAINMENT TRAY — AROCLOR 1254GC/MSEPA 8270DACTIVE RUNANALYTICAL INSTRUMENTCERTIFIED REPORTNELAP #NJ-CERT-0042ISO 17025:2017▪ SIGNED ▪ SEALEDASSAY LABS — FIELD-TO-REPORT SCHEMATIC REV.4.2© 2026
1,400+Analytes CataloguedAcross all matrices
38States CertifiedActive certifications
24 hrEmergency TATFastest turnaround
ISO 17025AccreditationNELAP + DoD ELAP
99.4%On-Time DeliveryFY 2025 average
NELAP-Accredited·ISO 17025:2017 Certified·State-Certified in 38 States·DoD ELAP Recognized·EPA Contract Laboratory Program·AIHA-LAP Accredited·OSHA Compliant Reporting·Chain-of-Custody Guaranteed·NELAP-Accredited·ISO 17025:2017 Certified·State-Certified in 38 States·DoD ELAP Recognized·EPA Contract Laboratory Program·AIHA-LAP Accredited·OSHA Compliant Reporting·Chain-of-Custody Guaranteed·
01 / Airborne Contaminants

Air Quality Testing

Indoor air quality surveys, stack emission testing, ambient air monitoring, and OSHA workplace exposure assessments. We deploy integrated sampling trains, sorbent tubes, and impingers — returning certified results against EPA Methods 18, 25A, and NIOSH criteria.

EPA TO-15EPA 25ANIOSH 1500NIOSH 7400ISO 16000-6

Sample Requirements

Volume / Mass1–6 L (Tedlar bag) / 7-day canister
ContainerSumma canister / sorbent tube
PreservationAmbient, dark, ≤4°C for sorbents
Hold Time30 days (canisters) / 14 days (tubes)
RegulationEPA NESHAP / OSHA PELs

Turnaround Tiers

Standard10 Business Days
Base
Rush48 Hours
+50%
Emergency24 Hours
+150%

Detection Limits & Methods

Analyte / ParameterMethodMDLUnitMatrix
Total VOCs (TVOC)EPA TO-150.5µg/m³Indoor Air
BenzeneEPA TO-150.1µg/m³Ambient
FormaldehydeNIOSH 20160.02ppmWorkplace
Respirable SilicaNIOSH 75000.01mg/m³Workplace
Asbestos FibersNIOSH 74000.01f/ccWorkplace
Carbon MonoxideEPA 100.5ppmStack
Nitrogen DioxideEPA 7E1.0ppmStack
PM2.5 / PM10EPA FRM0.5µg/m³Ambient

MDL = Method Detection Limit. All values represent routine laboratory conditions. Lower MDLs available upon request. Consult project manager for site-specific QC requirements.

02 / Aqueous Analysis

Water Chemistry

Drinking water compliance, groundwater characterization, stormwater discharge monitoring, and PFAS screening. Our aqueous lab runs EPA-certified methods under the Safe Drinking Water Act, NPDES, and RCRA programs. Chain-of-custody from field to bench.

EPA 524.2EPA 200.8EPA 537.1SM 4500EPA 8260B

Sample Requirements

Volume / Mass1 L (VOCs: 40 mL VOA vial)
ContainerAmber glass / HDPE / VOA vials
PreservationHCl or H₂SO₄ per parameter; ≤4°C
Hold Time7 days (VOCs) / 6 months (metals)
RegulationEPA MCLs / Safe Drinking Water Act

Turnaround Tiers

Standard10 Business Days
Base
Rush48 Hours
+50%
Emergency24 Hours
+150%

Detection Limits & Methods

Analyte / ParameterMethodMDLUnitMatrix
PFOA / PFOSEPA 537.10.4ng/LDrinking Water
Total PFAS (40-compound)EPA 5330.5ng/LGroundwater
VOCs (65-compound)EPA 524.20.5µg/LAqueous
ArsenicEPA 200.81.0µg/LDrinking Water
LeadEPA 200.81.0µg/LDrinking Water
Nitrate (as N)SM 4500-NO30.05mg/LAqueous
Total ColiformSM 9223BPresence/AbsencePotable
Hexavalent ChromiumEPA 218.60.5µg/LGroundwater

MDL = Method Detection Limit. All values represent routine laboratory conditions. Lower MDLs available upon request. Consult project manager for site-specific QC requirements.

03 / Solid Matrix Analysis

Soil & Sediment

Phase II ESA soil sampling, brownfield characterization, RCRA Subtitle C waste classification, and sediment toxicity testing. We process split-spoon, grab, and composite samples under ASTM D7458 QA protocols with full triplicate QC.

EPA 8270DEPA 6010CEPA 8082AEPA 8081AASTM D2216

Sample Requirements

Volume / Mass100–250 g (organics); 50 g (metals)
ContainerGlass jars (wide-mouth amber)
Preservation≤4°C, no headspace for VOCs
Hold Time14 days (VOCs) / 1 year (metals)
RegulationEPA RSLs / State Cleanup Standards

Turnaround Tiers

Standard10 Business Days
Base
Rush48 Hours
+50%
Emergency24 Hours
+150%

Detection Limits & Methods

Analyte / ParameterMethodMDLUnitMatrix
SVOCs (PAHs, 8270)EPA 8270D0.033mg/kgSoil
PCBs (Aroclors)EPA 8082A0.01mg/kgSoil/Sediment
RCRA Metals (8)EPA 6010C1.0mg/kgSoil
Total Petroleum HydrocarbonsEPA 8015B1.0mg/kgSoil
Pesticides (Chlorinated)EPA 8081A0.002mg/kgSoil
Dioxins / Furans (TEQ)EPA 8290A0.1pg/gSoil
Total Organic CarbonEPA 9060A0.1%Sediment
Grain Size DistributionASTM D422N/A% finesSediment

MDL = Method Detection Limit. All values represent routine laboratory conditions. Lower MDLs available upon request. Consult project manager for site-specific QC requirements.

04 / Building Materials

Asbestos & Lead

Pre-demolition asbestos surveys, clearance air testing, lead-based paint XRF screening, TCLP leachate classification, and wipe sampling for renovation compliance. Our PLM and TEM capabilities cover both bulk and airborne fiber analysis.

EPA PLMEPA TEMNIOSH 7400NIOSH 7402EPA 7420HUD Chapter 7

Sample Requirements

Volume / Mass1–5 cm² bulk; 100 cm² wipe
ContainerZip-lock poly bag (bulk); Ghost Wipe
PreservationAmbient, keep dry
Hold Time1 year (bulk) / 28 days (wipe)
RegulationEPA NESHAP / HUD / OSHA 1926

Turnaround Tiers

Standard10 Business Days
Base
Rush48 Hours
+50%
Emergency24 Hours
+150%

Detection Limits & Methods

Analyte / ParameterMethodMDLUnitMatrix
Asbestos (Bulk PLM)EPA PLM1%% by areaBulk Material
Asbestos (TEM Clearance)AHERA TEM70s/mm²Air
Asbestos (PCM Air)NIOSH 74000.01f/ccAir
Lead (Wipe, ICP)EPA 74201.0µg/ft²Wipe
Lead (Paint Chip)EPA 3050B10mg/kgSolid
Lead (XRF Screening)HUD XRF0.5mg/cm²Paint
TCLP LeadEPA 13110.1mg/LLeachate
Chromium (Wipe)EPA 6020A1.0µg/ft²Wipe

MDL = Method Detection Limit. All values represent routine laboratory conditions. Lower MDLs available upon request. Consult project manager for site-specific QC requirements.

05 / Occupational Exposure

Industrial Hygiene

Personal exposure monitoring, area air sampling, biological monitoring, and noise dosimetry for OSHA compliance programs. We design sampling strategies for chemical, physical, and biological hazards — delivering results against current PELs, TLVs, and Action Levels.

NIOSH 1500NIOSH 5000OSHA 42NIOSH 7600ASTM E1686

Sample Requirements

Volume / MassPersonal sampler (charcoal tube / filter)
ContainerSKC / MSA cassette / charcoal tube
PreservationSeal tube ends; ≤4°C for biologicals
Hold Time14 days (organics) / 30 days (metals)
RegulationOSHA PELs / ACGIH TLVs / NIOSH RELs

Turnaround Tiers

Standard10 Business Days
Base
Rush48 Hours
+50%
Emergency24 Hours
+150%

Detection Limits & Methods

Analyte / ParameterMethodMDLUnitMatrix
Total Hydrocarbons (PID)NIOSH 15000.5ppmPersonal Air
HexaneNIOSH 15000.1ppmPersonal Air
Isocyanates (TDI/MDI)OSHA 420.001ppmPersonal Air
Mold Spores (Culturable)ASTM D76581CFU/m³Indoor Air
Respirable DustNIOSH 06000.01mg/m³Personal Air
Heavy Metals (Personal)NIOSH 73000.1µg/m³Personal Air
Noise DosimetryOSHA 1910.9580dBA TWAWorkplace
Biological Monitoring (BEI)ACGIH BEIMatrix-specificUrine/Blood

MDL = Method Detection Limit. All values represent routine laboratory conditions. Lower MDLs available upon request. Consult project manager for site-specific QC requirements.

06 / Get Started

Request a Quote

Tell us your sample matrix, target analytes, and timeline. We'll return a fixed-price quote within 2 business hours.

samples / bottles

Full Test Menu

Download our complete 48-page capabilities binder. Every method, every matrix, every MDL. Updated quarterly.

1,400+ analytes catalogued
Method cross-reference index
State certification matrix
QA/QC summary by program
Sample container guide

No spam. Unsubscribe any time.